Back to top

WILLIAMS AIRWYAS INTUBATION

WILLIAMS AIRWYAS INTUBATION
WILLIAMS AIRWYAS INTUBATION
WILLIAMS AIRWYAS INTUBATION
WILLIAMS AIRWYAS INTUBATION
WILLIAMS AIRWYAS INTUBATION

WILLIAMS AIRWYAS INTUBATION Specification

  • Features
  • Open channel design, anatomical curve, allows fiberoptic intubation, single-use
  • Function
  • Airway management and intubation aid
  • Usage Type
  • Disposable
  • Shelf Life
  • Up to 5 years (unopened)
  • Storage Instructions
  • Store in a cool, dry place
  • Accuracy
  • High precision airway placement
  • Instruments Type
  • Emergency medical device
  • Equipment Type
  • Intubation Airway
  • Material
  • Medical-grade plastic
  • Condition
  • New
  • Technology
  • Manual airway insertion
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual
  • Use
  • Facilitate tracheal intubation
  • Dimension (L*W*H)
  • Standard adult and pediatric sizes available
  • Weight
  • Lightweight
  • Color
  • Transparent
  • Packaging
  • Individually packed
  • Reusable
  • No
  • Intended Patient
  • Adults and children
  • Compatible Devices
  • Fiberoptic bronchoscopes
  • Instructions for Use
  • Single-use, dispose after use
  • Sterility
  • Individually sterilized
  • Shape
  • Anatomically contoured
  • Latex-Free
  • Yes
 
 

About WILLIAMS AIRWYAS INTUBATION

Williams Airway Intubation

The Williams Airway Intubator is a device designed to assist in tracheal intubation. It is available in two adult sizes, 9 cm and 10 cm, each recommended for use with specific endotracheal tube sizes. The 10 cm size is recommended for use with up to an 8.5 ID endotracheal tube, while the 9 cm size is recommended for up to a 7.5 ID endotracheal tube.

This airway is cylindrical on the proximal half and open on the distal half of the lingual surface. It serves as an oral pharyngeal airway, a means of intubating the trachea, and a guide for fiberoptic laryngoscope placement. The Williams Airway Intubator is disposable and is intended for single use.

Studies comparing the Williams Airway Intubator with other intubating airways, such as the Berman Intubating Airway and the Ovassapian Fibreoptic Intubating Airway, have shown that the Williams Airway Intubator provides a better view of the glottis and a shorter time needed to complete bronchoscopy. In a study of 60 patients, the Williams Airway Intubator provided an unobstructed path for bronchoscopy in 48 out of 60 cases, compared to 12 cases with the Berman Intubating Airway



Reliable and Safe Airway Management

The WILLIAMS AIRWAY INTUBATION device ensures high-precision tracheal intubation for adults and children. Its sterilized, latex-free, single-use design reduces infection risks while providing clinicians with a safe, anatomically-contoured airway aid during emergencies or routine procedures.


Designed for Compatibility and Ease of Use

Engineered with an open channel and anatomical contour, this airway aids flexible intubation, particularly with fiberoptic bronchoscopes. Its transparent, lightweight construction enhances visibility and handling, making it ideal for both manual operation and portable use.

FAQ's of WILLIAMS AIRWYAS INTUBATION:


Q: How is the WILLIAMS AIRWAY INTUBATION device used during tracheal intubation?

A: This device is manually inserted into the patient's airway to guide and facilitate fiberoptic tracheal intubation. The open channel design allows for smooth passage of a bronchoscope and endotracheal tube, ensuring accurate placement, especially in challenging airways.

Q: What are the key benefits of using a single-use, sterile WILLIAMS AIRWAY INTUBATION device?

A: Single-use sterility significantly reduces the risk of patient cross-contamination and infection. The device is individually packed and ready for immediate use, ensuring optimal hygiene and patient safety in both routine and emergency situations.

Q: When should the WILLIAMS AIRWAY INTUBATION device be disposed of?

A: This airway is intended for single-use only and must be disposed of immediately after one procedure. Do not reuse the device under any circumstances, as this may compromise sterility and patient safety.

Q: Which patients are suitable for this intubation airway?

A: The device is specifically designed for airway management in both adult and pediatric patients, making it suitable for use across a wide range of clinical, emergency, and perioperative settings.

Q: Where should the device be stored for optimal shelf life?

A: Store the device in a cool, dry place and keep it within the sealed packaging until use. Proper storage ensures a shelf life of up to 5 years, provided the packaging remains unopened and intact.

Q: What medical settings can utilize the WILLIAMS AIRWAY INTUBATION device?

A: This airway device is ideal for use in hospitals, emergency departments, ambulances, and clinical settings where precise airway placement is required. Its portability and ease of manual operation make it suitable for a variety of care environments.

Price 1250 INR/ Piece

  • Minimum Order Quantity
  • 10 Pieces
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Intubation Devices And Accessories Category

LIGASURE VESSEL SEALER 1923

LIGASURE VESSEL SEALER 1923

Price 1550 INR / Piece

Minimum Order Quantity : 10 Pieces

Operating Type : Other, Electrosurgical

Portable : Yes

Equipment Type : Vessel Sealer

Features : Provides permanent vessel fusion, Minimal thermal spread, Reliable feedback system

Flexible Curved Scope Medical Mccoy Fiber Optic Laryngoscope  19500/set Score: 90/100

Flexible Curved Scope Medical Mccoy Fiber Optic Laryngoscope 19500/set Score: 90/100

Price 19500 INR / Piece

Minimum Order Quantity : 10 Pieces

Operating Type : Manual

Portable : Yes

Equipment Type : Flexible Curved Scope Medical McCoy Fiber Optic Laryngoscope

Features : Flexible curved blade, enhanced epiglottis elevation, removable light source, ergonomic grip

BABCOCK TISSUE FORCEPS

BABCOCK TISSUE FORCEPS

Price 1200 INR / Piece

Minimum Order Quantity : 10 Pieces

Operating Type : Other, Reusable, Handoperated

Portable : Yes

Equipment Type : Surgical Forceps

Features : Nonslip handle, atraumatic tip, corrosion resistant

TOWEL CLIP

TOWEL CLIP

Price 3500 INR / Piece

Minimum Order Quantity : 10 Pieces

Operating Type : Manual

Portable : Yes

Equipment Type : Towel Clip

Features : Corrosion resistant, Reusable, Autoclavable



Mark Enterprises
GST : 09CGDPG2368E1ZJ trusted seller