Back to top

BIPOLAR SEALER CUTTER

BIPOLAR SEALER CUTTER
BIPOLAR SEALER CUTTER

BIPOLAR SEALER CUTTER Specification

  • Instruments Type
  • Electrosurgical Unit
  • Function
  • Simultaneous Bipolar Sealing and Cutting
  • Frequency
  • 50-60 Hz
  • Display Type
  • Digital LED/Segmented Display
  • Storage Instructions
  • Store in Clean Dry Place, Avoid Direct Sunlight
  • Usage Type
  • Hospital, OT, Clinical, Surgeons Use
  • Accuracy
  • Precision Sealing; Error Rate <1%
  • Features
  • Automatic Vessel Recognition, Audible Feedback, Overheat Protection, Ergonomic Handle
  • Shelf Life
  • Up to 5 Years (Device); Single-use Accessories as per Manufacturer Guidance
  • Equipment Type
  • Bipolar Sealer Cutter
  • Material
  • Medical Grade Stainless Steel and Polymeric Components
  • Condition
  • New
  • Technology
  • Bipolar Electrosurgical Technology
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Low
  • Operating Type
  • Electric
  • Use
  • Tissue Sealing and Cutting in Surgical Procedures
  • Power Source
  • AC Powered
  • Power Consumption
  • 125-300 W (Depending on Model)
  • Voltage
  • 220-240 V, 50/60 Hz Compatible
  • Dimension (L*W*H)
  • Approx. 340 x 270 x 150 mm
  • Weight
  • Approx. 4.2 kg
  • Color
  • White/Blue (Standard)
  • Response Time
  • <1 Second Activation
  • Compatible Procedures
  • Laparoscopy, Open Surgery, ENT, Gynecology, General Surgery
  • Maximum Vessel Sealing Capacity
  • Up to 7 mm diameter vessels
  • Accessories Provided
  • Bipolar Forceps, Cable, Cutter, Foot Switch, User Manual
  • Safety Features
  • Automatic Power Off, Audible & Visual Alarms, Insulation Fail Indicators
  • Sterilization
  • Device Wipeable; Accessories Autoclavable or Disposable
  • Control Mode
  • Foot Switch and Hand Activation
  • Compliance
  • CE Marked, ISO 13485 Certified
  • Temperature Range
  • 10°C to 40°C (Operating), -10°C to +50°C (Storage)
  • Cable Length
  • 2 to 3 Meters
 
 

About BIPOLAR SEALER CUTTER

Bipolar Sealer Cutter

a specialized surgical instrument used in laparoscopic, thoracoscopic, and open surgeries to seal and cut blood vessels and tissue structures using controlled energy. These instruments utilize bipolar energy technology, which involves two electrodes at the tip that deliver electrical energy to heat and seal tissue clamped between them, minimizing thermal spread to surrounding areas. The primary function is to provide hemostasis by sealing vessels and then cutting them in a single step, improving surgical efficiency and safety.

These tools are designed for precision and are commonly used in general, gynecological, and urological procedures. They are typically constructed from medical-grade stainless steel, making them reusable and autoclavable. The instruments often feature an ergonomic handle for a secure grip and are available in various sizes, with a common shaft diameter of 5mm and a length of approximately 320-330mm. Some models, like those from Vishal Surgical Co., are compatible with specific systems such as Storz and come with a dedicated bipolar cable for immediate use.

Different manufacturers offer variations, including models with gold jaws for enhanced performance , and some are available as reusable or disposable options. The vessel sealing capacity can extend up to 7mm in diameter. These instruments are manufactured in India by companies such as ESC Medicams, Vishal Surgical Co., IndoSurgicals, Kara Mediclust Pvt Ltd, Tannu Surgical Works, and Rudra Surgical Works



Versatile Surgical Applications

This bipolar sealer cutter adapts efficiently to multiple surgical specialties including laparoscopy, open surgery, ENT, gynecology, and general surgical procedures. Its advanced sealing and cutting functionality can handle vessels up to 7 mm diameter, ensuring dependable hemostasis and improving surgical workflow. Surgeons benefit from the combination of precision and speed in diverse operating environments.


Enhanced Safety Features

Safety comes first with built-in features such as automatic power off, insulation fail indicators, and both audible and visual alarms. These safeguards reduce the risk of electrical or thermal injury, while overheat protection and automatic vessel recognition contribute to procedural confidence. The unit's low noise level and quick response support a smooth surgical experience.


Ease of Use and Maintenance

The device supports both foot switch and hand activation for ergonomic flexibility. Accessories such as bipolar forceps, cables, cutters, and foot switches are easy to sterilize-either by autoclave or via disposable use-ensuring hygiene compliance. Digital LED displays provide real-time feedback, while portability and low weight make this unit easy to transport and store in various clinical settings.

FAQ's of BIPOLAR SEALER CUTTER:


Q: How does the bipolar sealer cutter ensure safe vessel sealing during surgery?

A: The device incorporates advanced safety features such as automatic power-off, audible and visual alarms, and insulation fail indicators. Additionally, overheat protection and automatic vessel recognition further reduce risks, ensuring precise vessel sealing up to 7 mm in diameter.

Q: What types of surgical procedures can this bipolar sealer cutter be used for?

A: This equipment is suitable for a wide range of procedures, including laparoscopy, open surgery, ENT, gynecology, and general surgery. Its versatility makes it ideal for use in hospitals, operating theaters, and clinical settings.

Q: When should the included accessories be sterilized or replaced?

A: Autoclavable accessories, such as bipolar forceps and cutters, should be sterilized after each use following standard protocols. Disposable accessories should be replaced per the manufacturer's guidelines after single use to maintain safety and hygiene.

Q: Where should the bipolar sealer cutter be stored when not in use?

A: Store the device in a clean, dry environment, away from direct sunlight and temperature extremes. The recommended storage temperature range is -10C to +50C to preserve the equipment's functionality and extend its shelf life.

Q: What is the activation process for the bipolar sealer cutter during procedures?

A: Surgeons can activate the device using either the hand activation mode or the foot switch, depending on ergonomic preference. The response time is less than one second, allowing for immediate operation and seamless workflow in surgery.

Q: What are the benefits of using this bipolar sealer cutter in surgical practice?

A: This device offers simultaneous sealing and cutting, precision with an error rate below 1%, fast response time, and enhanced safety, all in a portable and easy-to-use system. These advantages help streamline surgical procedures, improve patient outcomes, and increase efficiency in the operating room.

Price 1950 INR/ Piece

  • Minimum Order Quantity
  • 10 Pieces
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Intubation Devices And Accessories Category

LARY SEAL PRO

LARY SEAL PRO

Price 1650 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Portable : Yes

Technology : Advanced Vessel Sealing

Color : White & Blue

HYGROVENT FILTER MOISTURE EXCHANGER

HYGROVENT FILTER MOISTURE EXCHANGER

Price 1250 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Portable : Yes

Technology : Hydrophobic Membrane Filtration

Color : Transparent with Blue/White Cap

TRUSHIELD NXT DERSING

TRUSHIELD NXT DERSING

Price 1455 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Portable : Yes

Technology : Advanced surface protection

Color : Milky white liquid

Transparent Circular Pediatric Silicone Face Mask

Transparent Circular Pediatric Silicone Face Mask

Price 1450 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Portable : Yes

Technology : Molded, Transparent Silicone

Color : Transparent



Mark Enterprises
GST : 09CGDPG2368E1ZJ trusted seller