Back to top

MOUTH GAG DAVIS BOYLE

MOUTH GAG DAVIS BOYLE
MOUTH GAG DAVIS BOYLE
MOUTH GAG DAVIS BOYLE
MOUTH GAG DAVIS BOYLE

MOUTH GAG DAVIS BOYLE Specification

  • Usage Type
  • Surgical, Hospital Use
  • Features
  • Corrosion Resistant, Reusable, Autoclavable, Smooth Finish
  • Shelf Life
  • Long (Reusable with proper sterilization)
  • Function
  • Mouth Opening & Retraction
  • Storage Instructions
  • Store in a dry, sterilized environment
  • Accuracy
  • Instrument - Not a measuring device
  • Instruments Type
  • Surgical Retractor
  • Equipment Type
  • Mouth Gag
  • Material
  • Stainless Steel
  • Condition
  • New
  • Technology
  • Manual
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual
  • Use
  • Used to keep the mouth open during oral and throat surgeries
  • Dimension (L*W*H)
  • As per standard instrument size (approx. 15 cm length)
  • Weight
  • Approx. 200 grams
  • Color
  • Silver
 
 

About MOUTH GAG DAVIS BOYLE

Mouth gags are used to keep the patients mouth open during oral surgery, leaving both hands of the surgeon free to operate.
The Boyle Davis mouth gag consists of the Davis gag, a frame that serves to hold the mouth open and the Boyle tongue depressor to hold the tongue down. The tongue depressor comes in several sizes, from pediatric to adult. The instrument is assembled by sliding the tongue blade into the frame. The mouth gag is held in position using the Draffin bipod stand.

Versatile Design for Oral and Throat Procedures

The Davis Boyle Mouth Gag is crafted to meet the needs of ENT surgeons performing tonsillectomies and various oral or throat procedures. Its ergonomic ratchet handle allows precise, adjustable opening, while the fenestrated, curved blades ensure secure mouth retraction without compromising patient comfort. Multiple variants suit both adults and pediatric patients.


Safety and Durability Assured

Manufactured from premium stainless steel, this mouth gag offers corrosion proofing and is both latex- and lead-free, reducing the risk of allergies and enhancing patient safety. The instrument can be sterilized by autoclaving, ensuring it meets strict hygiene protocols and boasts a long shelf life with repeated use.


Simple to Use and Maintain

Designed for ease of operation, the Davis Boyle Mouth Gag operates quietly and manually, without complex setup or mounting required. Its portable and lightweight form makes it convenient for hospital use, and it can be stored safely in a dry, sterilized environment for repeated procedures.

FAQ's of MOUTH GAG DAVIS BOYLE:


Q: How is the Davis Boyle Mouth Gag used during surgical procedures?

A: The Davis Boyle Mouth Gag is used to keep the patient's mouth open, providing clear access to oral and throat regions during surgeries like tonsillectomy. The adjustable ratchet handle allows controlled retraction tailored to each patient, ensuring stability throughout the procedure.

Q: What steps should be followed for sterilizing the Davis Boyle Mouth Gag?

A: After each use, the instrument should be thoroughly cleaned and then sterilized in an autoclave, as it is designed to withstand high sterilization temperatures. It should always be stored in a dry, sterilized environment to maintain its condition.

Q: When is it most appropriate to use the Davis Boyle Mouth Gag?

A: This mouth gag is ideal for surgeries involving the oral cavity or throat, particularly tonsillectomies and similar procedures that require prolonged mouth opening and retraction for better visibility and access.

Q: Where can the Davis Boyle Mouth Gag be used?

A: It is intended for use in clinical or hospital surgical settings, including ENT departments and operating theatres. The instrument is compatible for both adult and pediatric patients, depending on the selected variant.

Q: What are the main benefits of using this mouth gag?

A: The Davis Boyle Mouth Gag is reusable, corrosion-resistant, and made from safe, latex-free materials. It allows for precise mouth opening and consistent retraction, helping maintain a clear surgical field and enhancing procedural efficiency.

Q: Is there any special process for storing the instrument after use?

A: Following cleaning and sterilization, the mouth gag should be kept in a dry, sterile environment, such as its provided peel pouch or box, to preserve its integrity and readiness for future procedures.

Q: What makes the Davis Boyle Mouth Gag suitable for both adults and children?

A: The mouth gag has universal compatibility with variants available for both adult and pediatric patients, ensuring appropriate sizing and safe, effective use in all age groups.

Price 10 INR/ Piece

  • Minimum Order Quantity
  • 10 Pieces
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Intubation Devices And Accessories Category

ELITE LATERAL LEG POSITIONER

ELITE LATERAL LEG POSITIONER

Price 1250 INR / Piece

Minimum Order Quantity : 10 Pieces

Function : To prevent pressure ulcers and nerve damage by stabilizing the leg position

Weight : Approx. 1 kg

Portable : Yes

Color : Blue

Adjustable Cuffed Extended lenth Tracheotomy

Adjustable Cuffed Extended lenth Tracheotomy

Price 1650 INR / Piece

Minimum Order Quantity : 10 Pieces

Function : Facilitates airway support

Weight : Lightweight

Portable : Yes

Color : White

VENTURI MASK WITH SINGLE DILUTER

VENTURI MASK WITH SINGLE DILUTER

Price 1250 INR / Piece

Minimum Order Quantity : 10 Pieces

PARALLEL Y PIECE

PARALLEL Y PIECE

Price 1650 INR / Piece

Minimum Order Quantity : 10 Pieces



Mark Enterprises
GST : 09CGDPG2368E1ZJ trusted seller