Back to top

COVIDIEN GIA STAPLER 6038S

COVIDIEN GIA STAPLER 6038S
COVIDIEN GIA STAPLER 6038S
COVIDIEN GIA STAPLER 6038S
COVIDIEN GIA STAPLER 6038S
COVIDIEN GIA STAPLER 6038S

COVIDIEN GIA STAPLER 6038S Specification

  • Shelf Life
  • 3 Years
  • Instruments Type
  • Surgical Stapler
  • Storage Instructions
  • Store in a Cool, Dry Place
  • Accuracy
  • High Precision Tissue Closure
  • Features
  • Consistent Staple Formation, Safety Lock Mechanism, Ergonomic Handle, Reloadable Cartridges
  • Usage Type
  • Single Use, Disposable
  • Function
  • Stapling and Transection of Tissue
  • Measurement Range
  • 38mm Staple Line
  • Equipment Type
  • Linear Cutter Stapler
  • Material
  • Medical Grade Stainless Steel and Polymer
  • Condition
  • New
  • Technology
  • Mechanical Stapling
  • Portable
  • Yes, Disposable
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent Operation
  • Operating Type
  • Manual
  • Use
  • Surgical Stapling for Tissue and Organ Transection
  • Power Source
  • Manual
  • Dimension (L*W*H)
  • 38mm Staple Line Length
  • Weight
  • Lightweight (Single Use)
  • Color
  • White / Blue
  • Sterility
  • Sterile, EO Gas
  • Handle Type
  • Ergonomic, Easy Grip
  • Intended Use
  • General Surgery, Thoracic Surgery, Gastrointestinal Surgery
  • Model Number
  • 6038S
  • Row Formation
  • 3 Rows of Staples
  • Staple Size
  • 3.8mm
  • Cartridge Type
  • Reloadable Cartridges Supported
 
 

About COVIDIEN GIA STAPLER 6038S

Covidien GIA Stapler

The COVIDIEN GIA Stapler 6038S is a reloadable stapler designed for use in surgical procedures. It is part of the DST Series, which features a unique Tri-Staple technology that places two double-staggered rows of titanium staples while simultaneously cutting and dividing tissue between the two rows.

Key Features:
  • Staple size: 3.8mm
  • Staple height (closed): 1.5mm
  • Color code: Blue
  • Number of reloads: Up to 7 times
  • Total number of firings: 8 rings per instrument
  • Number of staples: 84
  • Staple cross-section: 0.19 x 0.30mm
  • Rows of staples: 4
  • Length of staple line: 84mm
Technical Specifications:
  • Instrument length: 60mm
  • Instrument height: 3.0, 3.5, 4.0mm (varies depending on tissue thickness)
  • Reload cartridge: GIA6038L
Clinical Applications:

The COVIDIEN GIA Stapler 6038S is intended for use in various surgical procedures, including gastrointestinal, thoracic, and general surgery. Its unique Tri-Staple technology and reloadable design make it suitable for applications where multiple firings are required.Covidien GIA Stapler

The COVIDIEN GIA Stapler 6038S is a reloadable stapler designed for use in surgical procedures. It is part of the DST Series, which features a unique Tri-Staple technology that places two double-staggered rows of titanium staples while simultaneously cutting and dividing tissue between the two rows.

Key Features:
  • Staple size: 3.8mm
  • Staple height (closed): 1.5mm
  • Color code: Blue
  • Number of reloads: Up to 7 times
  • Total number of firings: 8 rings per instrument
  • Number of staples: 84
  • Staple cross-section: 0.19 x 0.30mm
  • Rows of staples: 4
  • Length of staple line: 84mm
Technical Specifications:
  • Instrument length: 60mm
  • Instrument height: 3.0, 3.5, 4.0mm (varies depending on tissue thickness)
  • Reload cartridge: GIA6038L
Clinical Applications:

The COVIDIEN GIA Stapler 6038S is intended for use in various surgical procedures, including gastrointestinal, thoracic, and general surgery. Its unique Tri-Staple technology and reloadable design make it suitable for applications where multiple firings are required.



Precision and Reliability in Surgery

The COVIDIEN GIA Stapler 6038S incorporates advanced mechanical stapling technology to deliver high-precision tissue closure with each use. Its 3-row staple formation and consistent staple quality minimize the risk of leakage or bleeding, ensuring reliable surgical outcomes. The lightweight and ergonomic design makes it comfortable to handle, optimizing workflow efficiency for surgeons.


Ease of Use and Safety Features

Designed with an intuitive ergonomic handle for easy grip, this stapler promotes greater control and maneuverability in surgical environments. The reloadable cartridge system allows swift replacement during extended procedures, while the safety lock mechanism helps prevent accidental firing, enhancing overall surgical safety.


Ideal for Various Surgical Applications

This stapler is intended for single use in general, thoracic, and gastrointestinal surgeries, making it a versatile choice for numerous tissue and organ transection procedures. Its portable and compact design makes it suitable for different clinical settings, and its sterile, EO gas-treated construction ensures infection prevention.

FAQ's of COVIDIEN GIA STAPLER 6038S:


Q: How is the COVIDIEN GIA Stapler 6038S used during surgical procedures?

A: Surgeons use the COVIDIEN GIA Stapler 6038S to staple and transect tissue or organs during general, thoracic, or gastrointestinal surgeries. The device is manually operated and features an ergonomic handle for precise control, while the reloadable cartridge system supports efficient workflow.

Q: What are the benefits of the 3-row staple formation in the COVIDIEN GIA 6038S stapler?

A: The 3-row staple formation provides enhanced security by delivering uniform, high-precision tissue closure. This design minimizes the risk of post-surgical bleeding or leaks, contributing to safer and more reliable outcomes.

Q: When should the cartridge be reloaded, and how is it done?

A: The cartridge should be reloaded whenever it is depleted or a new staple line is required. To reload, simply remove the used cartridge and insert a new, compatible reloadable cartridge, adhering to sterilization protocols to maintain safety.

Q: Where can this stapler be used, and is it portable for use in multiple locations?

A: The COVIDIEN GIA Stapler 6038S is suitable for use in hospitals, surgical centers, and clinical environments. Its lightweight, compact, and portable design makes it easy to transport and utilize in different operating rooms or settings.

Q: What storage conditions are recommended for this stapler prior to use?

A: Store the stapler and cartridges in a cool, dry environment, away from direct sunlight. Proper storage helps maintain sterility and optimal performance until the product's 3-year shelf life expires.

Q: What safety measures are included in the COVIDIEN GIA 6038S linear cutter stapler?

A: The stapler features a safety lock mechanism to reduce the risk of accidental firing and ensure user and patient safety during surgical procedures.

Q: What materials are used in the construction of the COVIDIEN GIA 6038S, and why?

A: This stapler is constructed from medical-grade stainless steel and polymer, chosen for their durability, corrosion resistance, and compliance with medical safety standards, ensuring consistent and safe performance.

Price 1550 INR/ Piece

  • Minimum Order Quantity
  • 10 Pieces
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Intubation Devices And Accessories Category

Fluoroplastic Partial Prosthesis ( PORP )

Fluoroplastic Partial Prosthesis ( PORP )

Price 1250 INR / Piece

Minimum Order Quantity : 10 Pieces

Wall Mounted : No

Shelf Life : 5 Years

Instruments Type : ENT Surgical Prosthesis

Weight : <1g

PROCTOSCOPE BRASS INSTRUMENT

PROCTOSCOPE BRASS INSTRUMENT

Price 1850 INR / Piece

Minimum Order Quantity : 10 Pieces

Wall Mounted : No

Shelf Life : Long Life

Instruments Type : Surgical Instrument

Weight : Approx. 150250 grams

Epistaxis Balloon Catheter

Epistaxis Balloon Catheter

Price 1950 INR / Piece

Minimum Order Quantity : 10 Pieces

Wall Mounted : No

Shelf Life : 5 Years

Instruments Type : Medical Catheter

Weight : Approx. 1020 g

FLEXI ARM WITH ITS STANDARD ACCESSORIES

FLEXI ARM WITH ITS STANDARD ACCESSORIES

Price 1950 INR / Piece

Minimum Order Quantity : 10 Pieces

Wall Mounted : Other, Optional (Wall, Table, or Ceiling Mounted)

Shelf Life : 10+ years (with proper maintenance)

Instruments Type : Flexible Extraction Accessory

Weight : Approx. 24 kg (excluding accessories)



Mark Enterprises
GST : 09CGDPG2368E1ZJ trusted seller