TULIP ERYBANK ANTI-H LECTIN

TULIP ERYBANK ANTI-H LECTIN
TULIP ERYBANK ANTI-H LECTIN
TULIP ERYBANK ANTI-H LECTIN
TULIP ERYBANK ANTI-H LECTIN

TULIP ERYBANK ANTI-H LECTIN Specification

  • Accuracy
  • High subject to proper handling and technique
  • Frequency
  • Single use per test
  • Function
  • Detects H antigen for blood grouping
  • Shelf Life
  • 12 Months
  • Features
  • Ready to use, rapid test, specific for H antigen
  • Instruments Type
  • Blood Grouping Reagent
  • Usage Type
  • Laboratory Diagnostics
  • Measurement Range
  • Detects presence or absence of H antigen on RBCs
  • Storage Instructions
  • Store at 2C - 8C. Do not freeze. Protect from light.
  • Equipment Type
  • Reagent
  • Material
  • Liquid (Biological reagent)
  • Condition
  • New
  • Technology
  • Serological
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Operating Type
  • Manual
  • Use
  • Blood Grouping; Detection of H antigen on red blood cells
  • Dimension (L*W*H)
  • Vial with 5 ml content (exact dimensions not specified)
  • Weight
  • Approx. vial weight: 20 g
  • Color
  • Colorless to pale yellow
  • Pack Size
  • 5 ml vial
  • Test Principle
  • Agglutination
  • Intended Use
  • Professional use only, for in vitro diagnostic use
  • Specificity
  • High specificity for H antigen (Bombay phenotype detection)
  • Lot Number & Expiry
  • Printed on the label
  • Disposal
  • Biohazard discard after use
  • Instructions For Use
  • Refer to package insert for detailed procedure
  • Regulatory Compliance
  • IVD CE Marked
  • Sample Type
  • Human red blood cells (RBC) suspension
  • Presentation
  • Dropper capped vial
  • Compatibility
  • Compatible with standard blood grouping methods
 
 

About TULIP ERYBANK ANTI-H LECTIN



TULIP ERYBANK ANTI-H LECTIN is a pristine, reliable reagent designed for professional, in vitro diagnostic applications in blood typing. Engineered with immaculate precision, it offers high specificity for H antigen detection (ideal for identifying the rare Bombay phenotype). Its performance is marked by real-time operation and manual testing through an easy agglutination principle. The 5 ml dropper-capped vial is portable, ready-to-use, and colorless to pale yellow, ensuring a terrific order experience for laboratories seeking best price, accuracy, and regulatory compliance. Always store between 2C-8C.

Application and Usage Insights for Effective Blood Grouping

TULIP ERYBANK ANTI-H LECTIN is expertly designed for use in hospital blood banks, diagnostic laboratories, and research institutions. To achieve optimal results, always follow the detailed instructions in the package insert. Intended for laboratory diagnostics, this reagent is utilized for the qualitative detection of the H antigen on human red blood cells, making it indispensable for precise blood grouping and Bombay phenotype detection.


Export Solutions and Sample Services - Immediate Stock Exchange

TULIP ERYBANK ANTI-H LECTIN is available for export to numerous countries, including priority markets across Asia, Africa, and Europe. We provide sample vials for evaluation under our clear sample policy-simply exchange details and arrange a drop-off or shipment. Stock is always ready to fulfill trader and wholesaler requirements efficiently, ensuring swift order processing and optimal satisfaction.


FAQ's of TULIP ERYBANK ANTI-H LECTIN:


Q: How is TULIP ERYBANK ANTI-H LECTIN typically used in clinical laboratories?

A: This reagent is used for the rapid detection of the H antigen on human red blood cells, aiding in blood grouping and the identification of the Bombay phenotype. It operates via an agglutination test principle and is compatible with standard blood grouping methodology.

Q: What is the process for handling and disposing of the TULIP ERYBANK ANTI-H LECTIN after testing?

A: After single-use testing, the vial should be discarded as biohazard waste in line with laboratory safety protocols. Always refer to the lot number and expiry on the label before use.

Q: Where can I find detailed instructions for using TULIP ERYBANK ANTI-H LECTIN?

A: Complete usage directions and recommended procedural steps are provided in the package insert included with each vial. It is crucial to follow these instructions for pristine results and optimal accuracy.

Q: What benefits does the TULIP ERYBANK ANTI-H LECTIN offer compared to alternative reagents?

A: With its high specificity for the H antigen, CE marked compliance, and rapid, ready-to-use format, this reagent ensures immaculate, accurate detection crucial for transfusion safety and rare blood group identification.

Q: When should TULIP ERYBANK ANTI-H LECTIN be used during blood typing?

A: It is used when checking for the presence or absence of the H antigen, especially important in cases suspected of Bombay phenotype or when conventional blood grouping reagents yield unexpected results.

Price 500 INR/ Piece

  • Minimum Order Quantity
  • 10 Pieces
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Intubation Devices And Accessories Category

silicone bubble cpap mask

silicone bubble cpap mask

Price 1450 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Material : Other, Medical Grade Silicone

Color : Transparent

Use : Respiratory Support (CPAP Therapy)

FENESTRATED MEDIUM GRASPING FORCEP FHBR

FENESTRATED MEDIUM GRASPING FORCEP FHBR

Price 1550 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Material : Other, Stainless Steel

Color : Metallic Silver

Use : Laparoscopic Surgery, Grasping Tissue

COUNTER SCISSOR SS BRASS HANDLE

COUNTER SCISSOR SS BRASS HANDLE

Price 1250 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Material : Other, Stainless Steel (Blades), Brass (Handle)

Color : Silver (Blades) & Brass (Handle)

Use : Cutting applications in retail or hardware counters

OASIS HEEL PADS

OASIS HEEL PADS

Price 1500 INR / Piece

Minimum Order Quantity : 10 Pieces

Condition : New

Material : Other, Silicone Gel

Color : Transparent

Use : Foot Comfort and Pressure Relief



Mark Enterprises
GST : 09CGDPG2368E1ZJ trusted seller